Hamall
PROCESS INSTRUMENTS
COMPLETE PROCESS  SOLUTIONS
Home linkProducts linkInfo request linkSearch linkStock list link

KROHNE Variable Area Flowmeters
H 250

H 250 variable area flowmeter

Variable Area Flowmeter with metal tube.

Measuring Range
min.
max.
Water (20°C)
2,5 l/h
100 000 l/h
Air*
70 l/h
600 000 l/h
Operational limits
max. pressure
max. temperature
16 to 100 bar
300°C
Materials
Meas. tube


wetted parts

stainless steel or Hastelloy B, C
or others (on request)

stainless steel
Accuracy class

Connection


Size

Limit switches
Transmitters
1,6

Flanges DN 15 to 100, sanitary connection

250 mm

SC 3,5-N0 SJ 3,5-E2
electrical or pneumatic Ex-i transmitter HARTŪ

*(1,013 bar abs., 20°C)

BACK   Download pdf datasheet(961KB)  Download manual(1.395MB)


HAMALL PROCESS INSTRUMENTS, DEVONPARK MILLS, ALEXANDRA STREET, TILLICOULTRY, CLACKMANNANSHIRE, SCOTLAND, UK. FK13 6HP
TEL NO : 44 (0)1259 753753 FAX NO : 44 (0)1259 752770
Mail to sales sales@hamall.co.uk