KROHNE Variable Area Flowmeters
DK 37M, DK37E

Variable
Area Flowmeter for low flow rates with built in needle valve
Mechanical indicator (DK37M) or 2-wire 4..20mA (DK37E)
Measuring Range
min.
max. |
Water (20°C)
0,3 l/h
100 l/h |
Air*
5 l/h
3 400 l/h |
Operational limits
max. pressure
max. temperature |
130 bar (optional 600 bar)
150 °C |
|
Materials
Meas. tube
wetted parts |
stainless steel
PTFE, PFA, Viton |
|
Accuracy class
Connection
Length
Limit switches
Output
|
2,5
1/4 " NPT
153 mm
SC 2-N0
4-20mA |
|
*(1,013 bar abs., 20°C)
BACK Download pdf datasheet(161KB) Download manual(895KB)
HAMALL PROCESS INSTRUMENTS, DEVONPARK MILLS, ALEXANDRA STREET, TILLICOULTRY, CLACKMANNANSHIRE, SCOTLAND, UK. FK13 6HP
TEL NO : 44 (0)1259 753753 FAX NO : 44 (0)1259 752770
sales@hamall.co.uk |