KROHNE Variable Area Flowmeters
DK 32, DK34

DK32/34 metal tube variable area flowmeter with metal measuring tube and built-in needle valve.
Measuring Range
min.
max. |
Water (20°C)
0,3 l/h
100 l/h |
Air*
5 l/h
3 400 l/h |
Operational limits
max. pressure
max. temperature |
130 bar (Optional 600 bar)
150 °C |
|
Materials
Meas. tube
wetted parts |
stainless steel
stainless steel, PTFE, Viton |
|
Accuracy class
Connection
Size
Limit switches
|
4
1/4 " NPT or R1/4
DK 32 horizontal, DK34 vertical
119 mm (DK32), 110 mm (DK 34)
SC 2-N0
|
|
*(1,013 bar abs., 20°C)
BACK Download pdf datasheet(247KB) Download manual(593KB)
HAMALL PROCESS INSTRUMENTS, DEVONPARK MILLS, ALEXANDRA STREET, TILLICOULTRY, CLACKMANNANSHIRE, SCOTLAND, UK. FK13 6HP
TEL NO : 44 (0)1259 753753 FAX NO : 44 (0)1259 752770